T1 - Analysis of a diffusion dryer for the respiratory delivery of poorly water soluble drugs
AU - Pham, Stephen
AU - Wiedmann, Timothy S.
PY - 1999/1/1
Y1 - 1999/1/1
N2 - Purpose. The purpose of this study was to analyze a diffusion dryer as a means to remove organic solvents from aerosol particles of poorly water soluble drugs. Methods. Aerosols of methanol, ethanol, and ethyl acetate were generated with an ultrasonic nebulizer, and inflow to outflow concentration ratio of vapor in a annular charcoal column was determined as a function of time by gas chromotography at two to four different airflow rates. In addition, the particle transmission efficiency was determined with an ethanol solution of the test compound, budesonide. The results were analyzed with equations originally developed for assessing the loss of drug from intravenous tubing along with independent measures of the adsorption isotherm of the vapors onto charcoal. Results. Aerosol production was relatively constant with time, and the transmission of solid particles through the column occurred with efficiency nearing 100%. The inlet to outlet vapor concentration ratio was adequately described by a model of three resistances in series composed of the inner tube, the screen mesh, and the charcoal bed. Conclusions. The diffusion dryer was found to be satisfactory for the removal of methanol, ethanol, and ethyl acetate and the efficiency may be assessed from the adsorption isotherms on charcoal and the geometry of the dryer.
AB - Purpose. The purpose of this study was to analyze a diffusion dryer as a means to remove organic solvents from aerosol particles of poorly water soluble drugs. Methods. Aerosols of methanol, ethanol, and ethyl acetate were generated with an ultrasonic nebulizer, and inflow to outflow concentration ratio of vapor in a annular charcoal column was determined as a function of time by gas chromotography at two to four different airflow rates. In addition, the particle transmission efficiency was determined with an ethanol solution of the test compound, budesonide. The results were analyzed with equations originally developed for assessing the loss of drug from intravenous tubing along with independent measures of the adsorption isotherm of the vapors onto charcoal. Results. Aerosol production was relatively constant with time, and the transmission of solid particles through the column occurred with efficiency nearing 100%. The inlet to outlet vapor concentration ratio was adequately described by a model of three resistances in series composed of the inner tube, the screen mesh, and the charcoal bed. Conclusions. The diffusion dryer was found to be satisfactory for the removal of methanol, ethanol, and ethyl acetate and the efficiency may be assessed from the adsorption isotherms on charcoal and the geometry of the dryer.
KW - Aerosol
KW - Diffusion dryer
KW - Respiratory drug delivery
KW - Steroids
KW - Ultrasonic nebulizer
UR - http://www.scopus.com/inward/record.url?scp=0033451242&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033451242&partnerID=8YFLogxK
U2 - 10.1023/A:1018903426344
DO - 10.1023/A:1018903426344
M3 - Article
C2 - 10644074
AN - SCOPUS:0033451242
SN - 0724-8741
VL - 16
SP - 1857
EP - 1863
JO - Pharmaceutical research
JF - Pharmaceutical research
IS - 12
ER -