Anisotropic Polytetrafluoroethylene Cardiovascular Conduits Spontaneously Expand in a Growing Lamb Model

Anthony Azakie, John P. Carney, Matthew T. Lahti, Yuriy Moklyak, Richard W. Bianco

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background: Insertion of conduits from the right ventricle (RV) to the pulmonary artery (PA) is a commonly used technique for repair of congenital heart defects. The vast majority of infants and children will require reoperation and/or re-intervention to replace the conduit. Some children may require multiple reoperations, with the risk of death and morbidity increasing significantly with each subsequent operation. We evaluated the feasibility and performance of a relatively novel anisotropic conduit for cardiovascular repair in the growing lamb model. Materials and Methods: Lambs were allocated into a control (n = 3) or test (n = 4, anisotropic) conduit group. Control conventional polytetrafluoroethylene (PTFE) conduits or test anisotropic expanded PTFE (ePTFE) based test conduits measuring 10–11 mm in diameter were sewn as interpositional grafts in the main pulmonary artery (MPA) and followed up to 6 months. Clinical and echocardiographic evaluations were performed monthly with hemodynamic and angiographic assessment at 3 and 6 months. Results: Control conduits did not expand, all 3 animals developed one or more adverse events including tachypnea, ascites, inappetence, lethargy, and mortality due to severe right heart failure and significantly higher peak trans-conduit gradients (48.5 ± 5.1 p = 0.02). The test conduits spontaneously expanded up to 14.8 ± 0.8 mm in diameter, no adverse events were observed in any animals and trans-conduit gradients were significantly lower (27.0 ± 8.3, p = 0.02). Conclusions: Anisotropic ePTFE conduits can be safely implanted in growing lambs with stable hemodynamics. This spontaneously expanding anisotropic conduit may represent a novel approach to congenital heart repairs that would avoid the need for reoperation or multiple operations.

Original languageEnglish (US)
Pages (from-to)1348-1354
Number of pages7
JournalJournal of Investigative Surgery
Volume34
Issue number12
DOIs
StatePublished - 2021

Bibliographical note

Funding Information:
This work was funded by the Fred C. & Katherine B. Andersen Foundation. We thank the UMN Experimental Surgical Services Laboratory staff and students with their help in conducting the animal experiments; the UMN Research Animal Resources staff for their care and support of the research animals used in this study; Melanie Graham for her help with the editing process; Gurumurthy Hiremath for interventional cardiology expertise and helpful discussions.

Publisher Copyright:
© 2020 The Author(s). Published with license by Taylor & Francis Group, LLC.

Keywords

  • Growing lamb model
  • cardiac surgery
  • cardiovascular repair
  • conduits
  • congenital heart defects
  • heart

PubMed: MeSH publication types

  • Journal Article

Fingerprint

Dive into the research topics of 'Anisotropic Polytetrafluoroethylene Cardiovascular Conduits Spontaneously Expand in a Growing Lamb Model'. Together they form a unique fingerprint.

Cite this