Abstract
During 2004, two different wall assemblies using an exterior thermal and moisture management system (ETMMS) were used in the construction of two low-income projects in St. Paul, Minnesota. This paper discusses and compares the two types of wall assemblies, emphasizing the differences in construction methods and procedures. Comparisons include energy, moisture resistance, indoor air quality, constructability, and acceptance.
Original language | English (US) |
---|---|
Title of host publication | Buildings IX |
Subtitle of host publication | Thermal Performance of Exterior Envelopes of Whole Buildings |
Publisher | American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) |
ISBN (Electronic) | 9781931862608 |
State | Published - Jan 1 2004 |
Event | 9th International Conference on Thermal Performance of Exterior Envelopes of Whole Buildings 2004 - Clearwater, United States Duration: Dec 5 2004 → Dec 10 2004 |
Publication series
Name | Thermal Performance of the Exterior Envelopes of Whole Buildings |
---|---|
ISSN (Electronic) | 2166-8469 |
Conference
Conference | 9th International Conference on Thermal Performance of Exterior Envelopes of Whole Buildings 2004 |
---|---|
Country/Territory | United States |
City | Clearwater |
Period | 12/5/04 → 12/10/04 |
Bibliographical note
Publisher Copyright:© 2004 ASHRAE.