Contrast enhanced ultrasound imaging using adaptive third-order Volterra filter

Juan Du, Dalong Liu, Emad Ebbini

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Scopus citations

Abstract

We have previously demonstrated the ability of the post-beamforming Volterra filter (VF) to separate linear and nonlinear echo components in contrast-enhanced ultrasound (CEUS) application, including imaging tumor perfusion in vivo. Compared to pulse inversion, the quadratic and cubic components from a 3rd-order VF (ThOVF) produce the same or higher level of contrast without sacrificing bandwidth or frame rate. However, CEUS imaging of small vessels with high level of sensitivity and specificity remains a challenge using clinical probes. Imaging such fine structures with highly focused beams may improve the sensitivity and specificity of CEUS in some applications. We have used a concave 64-element, 3.5-MHz array (40-mm roc) and also a linear diagnostic array probe (HST 15-8), in cross sectional imaging a 200 μm cellulose tube embedded in a tissue-mimicking phantom. An infusion syringe pump was used to pump a saline solution with small concentration contrast agents or cellulose linear scatters through the cellulose tube. Different power settings were used when collecting the data. Pulse inversion data was acquired using positive and negative transmit pulses for each image line. An adaptive third order VF was applied to the beamformed data to separate the linear, quadratic, and cubic signal components. The quadratic and cubic components from the ThoVF were compared to the corresponding PI component with and without the UCA. The PSDs of the quadratic and cubic components of the ThOVF and the PI signal with and without UCA, all three signals show enhancement due to the presence of UCA in different frequency bands. The results also show that higher power setting result in larger value of temporal perfusion index (TPI) and better imaging quality. And compared with the linear array, concave dual-mode Ultrasound array (DMUA) has lower noise level and better enhancement because of the highly focused imaging beam matched to the target microvessel.

Original languageEnglish (US)
Title of host publicationIEEE International Ultrasonics Symposium, IUS
PublisherIEEE Computer Society
Pages1746-1749
Number of pages4
ISBN (Electronic)9781479970490
DOIs
StatePublished - Oct 20 2014
Event2014 IEEE International Ultrasonics Symposium, IUS 2014 - Chicago, United States
Duration: Sep 3 2014Sep 6 2014

Publication series

NameIEEE International Ultrasonics Symposium, IUS
ISSN (Print)1948-5719
ISSN (Electronic)1948-5727

Other

Other2014 IEEE International Ultrasonics Symposium, IUS 2014
Country/TerritoryUnited States
CityChicago
Period9/3/149/6/14

Bibliographical note

Publisher Copyright:
© 2014 IEEE.

Fingerprint

Dive into the research topics of 'Contrast enhanced ultrasound imaging using adaptive third-order Volterra filter'. Together they form a unique fingerprint.

Cite this