Coronary arterial compression testing by simultaneous balloon valvuloplasty and coronary angiography in an English bulldog with pulmonary valve stenosis

K. R.S. Morgan, C. Stauthammer, B. Stewart, W. Gordon-Evans, S. Arai, C. Baldo, D. Gruenstein

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

A 4-year-old male neutered English bulldog presented for heart murmur evaluation. Echocardiography identified severe pulmonic stenosis (an echocardiography-derived transpulmonary pressure gradient of 100 mmHg), and computed tomography confirmed the presence of an anomalous coronary artery with a prepulmonic course of the left coronary artery arising from the right coronary ostium. Before artificial pulmonic valve implantation, a coronary compression test was performed. A simultaneous aortic root angiogram and pulmonic balloon valvuloplasty revealed complete occlusion of the circumflex branch. Artificial valve implantation was aborted with concern for fatal coronary compression after implantation. Coronary compression testing is a critical component of the evaluation before catheter-based implantation of conduits across the pulmonic valve.

Original languageEnglish (US)
Pages (from-to)124-129
Number of pages6
JournalJournal of Veterinary Cardiology
Volume35
DOIs
StatePublished - Jun 2021

Bibliographical note

Funding Information:
The authors would like to thank Medtronic, Minneapolis, particularly Noah Barka, Tara Nahey, and Justin Sutkowski for the donation of the Melody valve™ and their technical expertise.

Publisher Copyright:
© 2021 Elsevier B.V.

Keywords

  • Anomalous
  • Conduit
  • Intervention
  • Pulmonic

PubMed: MeSH publication types

  • Case Reports
  • Journal Article

Fingerprint

Dive into the research topics of 'Coronary arterial compression testing by simultaneous balloon valvuloplasty and coronary angiography in an English bulldog with pulmonary valve stenosis'. Together they form a unique fingerprint.

Cite this