TY - JOUR
T1 - Effects of Continuous Accelerated Pacing on Cardiac Structure and Function in Patients With Heart Failure With Preserved Ejection Fraction
T2 - Insights From the myPACE Randomized Clinical Trial
AU - Wahlberg, Kramer J.
AU - Infeld, Margaret
AU - Plante, Timothy B.
AU - Novelli, Alexandra E.
AU - Habel, Nicole
AU - Burkhoff, Daniel
AU - Barrett, Trace
AU - Lustgarten, Daniel
AU - Meyer, Markus
N1 - Publisher Copyright:
© 2023 The Authors.
PY - 2024/1/2
Y1 - 2024/1/2
N2 - BACKGROUND: Heart failure with preserved ejection fraction ≥50% is prevalent with few evidence-based therapies. In a trial of patients with heart failure with preserved ejection fraction with specialized pacemakers, treatment with accelerated personalized pacing averaging 75 bpm (myPACE) markedly improved quality of life, NT-proBNP (N-terminal pro–brain natriuretic peptide), physical activity, and atrial fibrillation burden compared with the standard lower rate setting of 60 bpm (usual care). METHODS AND RESULTS: In this exploratory study, provider-initiated echocardiographic studies obtained before and after the trial were assessed for changes in left ventricular (LV) structure and function among participants who continued their pacing assignment. The analytic approach aimed to detect differences in standard and advanced echocardiographic parameters within and between study arms. Of the 100 participants, 16 myPACE and 20 usual care arm had a qualifying set of echocar-diograms performed a mean (SD) 3 (2.0) years apart. Despite similar baseline echocardiogram measures, sustained exposure to moderately accelerated pacing resulted in reduced septal wall thickness (in cm: myPACE 1.1 [0.2] versus usual care 1.2 [0.2], P=0.008) and lower LV mass to systolic volume ratio (in g/mL: myPACE 4.8 [1.9] versus usual care 6.8 [3.1], P=0.038) accompanied by a minor reduction in LV ejection fraction (in %: myPACE 55 [5] versus usual care 60 [5], P=0.015). These changes were paralleled by improvements in heart failure-related quality of life (myPACE Minnesota Living with Heart Failure Questionnaire improved by 16.1 [13.9] points, whereas usual care worsened by 6.9 [11.6] points, P<0.001). Markers of diastolic function and LV performance were not affected. CONCLUSIONS: Exposure to continuous accelerated pacing in heart failure with preserved ejection fraction is associated with a reduced LV wall thickness and a small amount of LV dilation with small reduction in ejection fraction.
AB - BACKGROUND: Heart failure with preserved ejection fraction ≥50% is prevalent with few evidence-based therapies. In a trial of patients with heart failure with preserved ejection fraction with specialized pacemakers, treatment with accelerated personalized pacing averaging 75 bpm (myPACE) markedly improved quality of life, NT-proBNP (N-terminal pro–brain natriuretic peptide), physical activity, and atrial fibrillation burden compared with the standard lower rate setting of 60 bpm (usual care). METHODS AND RESULTS: In this exploratory study, provider-initiated echocardiographic studies obtained before and after the trial were assessed for changes in left ventricular (LV) structure and function among participants who continued their pacing assignment. The analytic approach aimed to detect differences in standard and advanced echocardiographic parameters within and between study arms. Of the 100 participants, 16 myPACE and 20 usual care arm had a qualifying set of echocar-diograms performed a mean (SD) 3 (2.0) years apart. Despite similar baseline echocardiogram measures, sustained exposure to moderately accelerated pacing resulted in reduced septal wall thickness (in cm: myPACE 1.1 [0.2] versus usual care 1.2 [0.2], P=0.008) and lower LV mass to systolic volume ratio (in g/mL: myPACE 4.8 [1.9] versus usual care 6.8 [3.1], P=0.038) accompanied by a minor reduction in LV ejection fraction (in %: myPACE 55 [5] versus usual care 60 [5], P=0.015). These changes were paralleled by improvements in heart failure-related quality of life (myPACE Minnesota Living with Heart Failure Questionnaire improved by 16.1 [13.9] points, whereas usual care worsened by 6.9 [11.6] points, P<0.001). Markers of diastolic function and LV performance were not affected. CONCLUSIONS: Exposure to continuous accelerated pacing in heart failure with preserved ejection fraction is associated with a reduced LV wall thickness and a small amount of LV dilation with small reduction in ejection fraction.
KW - HFpEF
KW - pacing
KW - ventricular remodeling
UR - http://www.scopus.com/inward/record.url?scp=85181585700&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85181585700&partnerID=8YFLogxK
U2 - 10.1161/JAHA.123.032873
DO - 10.1161/JAHA.123.032873
M3 - Article
C2 - 38156545
AN - SCOPUS:85181585700
SN - 2047-9980
VL - 13
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 1
M1 - e9139
ER -