Evaluation of SrAl2O4:Eu, Dy phosphor for potential applications in thermoluminescent dosimetry

Xueyan Tang, Eric D. Ehler, Eric Brost, Damien C. Mathew

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Purpose: To evaluate the use of commercial-grade strontium aluminate phosphorescent powder as a thermoluminescent (TL) dosimeter for clinical radiotherapy beams. Materials and Method: Commercially available Eu2+, Dy3+ co-doped strontium aluminate powder (SrAl2O4:Eu, Dy) was annealed and then irradiated using 20 × 20 cm2 field size, with 6-MV (PDD10 = 70.7) and 18-MV (PDD10 = 79.4) photon beams and and 9-MeV (R50 = 3.6), 15 MeV (R50 = 5.9) and 18-MeV (R50 = 7.2) electron beams. To calibrate the relationship between the TL readings and the irradiated doses, TL glow curves were acquired for doses up to 600 cGy at all beam energies. For the percentage depth dose (PDD) measurement, the SrAl2O4:Eu, Dy powder was sandwiched by solid water phantoms, with varying thickness of solid water placed above to determine the depth. PDDs were measured at four representative depths and compared against the commissioning depth dose data for each beam energy. Results: Linear dose response models of doses up to 200 cGy were created for all beam energies. Superlinearity was observed with doses greater than 200 cGy. The PDD measurement acquired experimentally agrees well with the commissioning data of the medical linear accelerator. Trapping parameters such as order of kinetics, activation energy and frequency factor have been obtained via TL glow curve analysis. Conclusion: The linear dose response demonstrates that SrAl2O4:Eu, Dy is a potential TLD dosimeter for both electron beams and photon beams at different beam energies. The PDD measurements further support its potential use in quality assurance and radiation dosimetry.

Original languageEnglish (US)
Pages (from-to)191-197
Number of pages7
JournalJournal of Applied Clinical Medical Physics
Volume22
Issue number5
DOIs
StatePublished - May 2021

Bibliographical note

Publisher Copyright:
© 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Keywords

  • dose response
  • quality assurance
  • strontium aluminate
  • thermoluminescent dosimetry
  • trapping parameters

Fingerprint

Dive into the research topics of 'Evaluation of SrAl2O4:Eu, Dy phosphor for potential applications in thermoluminescent dosimetry'. Together they form a unique fingerprint.

Cite this