Halo Formation and Resolution at 7-Year Follow-Up After Sacroiliac Joint Fusion Revision: A Case Report

Jason J. Haselhuhn, Arthur Mercado, Paul Brian O. Soriano, David W. Polly

Research output: Contribution to journalArticlepeer-review

Abstract

Case:A 49-year-old woman presented with low back pain after a work-related injury. She failed 5 months of conservative management and subsequently underwent minimally invasive (MI) left sacroiliac joint (SIJ) fusion with 3 triangular titanium implants. Four months postoperatively, she developed recurrence of symptoms and radiographic halo phenomenon about the implants. The cephalad and caudal implants were replaced with threaded self-tapping implants, and the middle implant was unable to be removed. At 7-year follow-up, the halo phenomenon had resolved.Conclusion:This is an unusual case of radiographic halo phenomenon formation after MI SIJ fusion and halo resolution after subsequent revision.

Original languageEnglish (US)
Article numbere23.00199
JournalJBJS case connector
Volume13
Issue number3
DOIs
StatePublished - Aug 17 2023

Bibliographical note

Publisher Copyright:
© 2023 Lippincott Williams and Wilkins. All rights reserved.

Keywords

  • Sacroiliac joint fusion
  • halo phenomenon
  • radiolucencies
  • sclerotic rind

PubMed: MeSH publication types

  • Case Reports
  • Journal Article

Fingerprint

Dive into the research topics of 'Halo Formation and Resolution at 7-Year Follow-Up After Sacroiliac Joint Fusion Revision: A Case Report'. Together they form a unique fingerprint.

Cite this