Improved 1H body imaging at 10.5 T: Validation and VOP-enabled imaging in vivo with a 16-channel transceiver dipole array

Simon Schmidt, M. Arcan Ertürk, Xiaoxuan He, Tobey Haluptzok, Yiğitcan Eryaman, Gregory J. Metzger

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo. Methods: The inaccuracy of the electromagnetic model of the array was quantified based on B1+ and SAR data. Inter-subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16-channel array was assessed in simulation by comparison to a previously demonstrated 10-channel array. In vivo imaging of the prostate was performed demonstrating SAR-constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE). Results: The model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%. Conclusions: By validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.

Original languageEnglish (US)
Pages (from-to)513-529
Number of pages17
JournalMagnetic resonance in medicine
Volume91
Issue number2
DOIs
StatePublished - Feb 2024

Bibliographical note

Publisher Copyright:
© 2023 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Keywords

  • 10.5 T
  • MRI
  • body imaging
  • parallel transmit
  • ultra-high field imaging
  • validation

PubMed: MeSH publication types

  • Journal Article

Fingerprint

Dive into the research topics of 'Improved 1H body imaging at 10.5 T: Validation and VOP-enabled imaging in vivo with a 16-channel transceiver dipole array'. Together they form a unique fingerprint.

Cite this