TY - JOUR
T1 - Intubation biomechanics
T2 - Laryngoscope force and cervical spine motion during intubation in cadavers - Effect of severe distractive-flexion injury on C3-4 motion
AU - Hindman, Bradley J.
AU - Fontes, Ricardo B.
AU - From, Robert P.
AU - Traynelis, Vincent C.
AU - Todd, Michael M.
AU - Puttlitz, Christian M.
AU - Santoni, Brandon G.
N1 - Publisher Copyright:
©AANS, 2016.
PY - 2016/11
Y1 - 2016/11
N2 - OBJECTIVE: With application of the forces of intubation, injured (unstable) cervical segments may move more than they normally do, which can result in spinal cord injury. The authors tested whether, during endotracheal intubation, intervertebral motion of an injured C3-4 cervical segment 1) is greater than that in the intact (stable) state and 2) differs when a high- or low-force laryngoscope is used. METHODS: Fourteen cadavers underwent 3 intubations using force-sensing laryngoscopes while simultaneous cervical spine motion was recorded with lateral fluoroscopy. The first intubation was performed with an intact cervical spine and a conventional high-force line-of-sight Macintosh laryngoscope. After creation of a severe C3-4 distractive-flexion injury, 2 additional intubations were performed, one with the Macintosh laryngoscope and the other with a low-force indirect video laryngoscope (Airtraq), used in random order. RESULTS: During Macintosh intubations, between the intact and the injured conditions, C3-4 extension (0.3° ± 3.0° vs 0.4° ± 2.7°, respectively; p = 0.9515) and anterior-posterior subluxation (-0.1 ± 0.4 mm vs -0.3 ± 0.6 mm, respectively; p = 0.2754) did not differ. During Macintosh and Airtraq intubations with an injured C3-4 segment, despite a large difference in applied force between the 2 laryngoscopes, segmental extension (0.4° ± 2.7° vs 0.3° ± 3.3°, respectively; p = 0.8077) and anterior-posterior subluxation (0.3 ± 0.6 mm vs 0.0 ± 0.7 mm, respectively; p = 0.3203) did not differ. CONCLUSIONS: The authors' hypotheses regarding the relationship between laryngoscope force and the motion of an injured cervical segment were not confirmed. Motion-force relationships (biomechanics) of injured cervical intervertebral segments during endotracheal intubation in cadavers are not predicted by the in vitro biomechanical behavior of isolated cervical segments. With the limitations inherent to cadaveric studies, the results of this study suggest that not all forms of cervical spine injury are at risk for pathological motion and cervical cord injury during conventional high-force line-of-sight intubation.
AB - OBJECTIVE: With application of the forces of intubation, injured (unstable) cervical segments may move more than they normally do, which can result in spinal cord injury. The authors tested whether, during endotracheal intubation, intervertebral motion of an injured C3-4 cervical segment 1) is greater than that in the intact (stable) state and 2) differs when a high- or low-force laryngoscope is used. METHODS: Fourteen cadavers underwent 3 intubations using force-sensing laryngoscopes while simultaneous cervical spine motion was recorded with lateral fluoroscopy. The first intubation was performed with an intact cervical spine and a conventional high-force line-of-sight Macintosh laryngoscope. After creation of a severe C3-4 distractive-flexion injury, 2 additional intubations were performed, one with the Macintosh laryngoscope and the other with a low-force indirect video laryngoscope (Airtraq), used in random order. RESULTS: During Macintosh intubations, between the intact and the injured conditions, C3-4 extension (0.3° ± 3.0° vs 0.4° ± 2.7°, respectively; p = 0.9515) and anterior-posterior subluxation (-0.1 ± 0.4 mm vs -0.3 ± 0.6 mm, respectively; p = 0.2754) did not differ. During Macintosh and Airtraq intubations with an injured C3-4 segment, despite a large difference in applied force between the 2 laryngoscopes, segmental extension (0.4° ± 2.7° vs 0.3° ± 3.3°, respectively; p = 0.8077) and anterior-posterior subluxation (0.3 ± 0.6 mm vs 0.0 ± 0.7 mm, respectively; p = 0.3203) did not differ. CONCLUSIONS: The authors' hypotheses regarding the relationship between laryngoscope force and the motion of an injured cervical segment were not confirmed. Motion-force relationships (biomechanics) of injured cervical intervertebral segments during endotracheal intubation in cadavers are not predicted by the in vitro biomechanical behavior of isolated cervical segments. With the limitations inherent to cadaveric studies, the results of this study suggest that not all forms of cervical spine injury are at risk for pathological motion and cervical cord injury during conventional high-force line-of-sight intubation.
KW - Biomechanics
KW - Cadaver
KW - Cervical spine
KW - Endotracheal intubation
UR - http://www.scopus.com/inward/record.url?scp=85012849135&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85012849135&partnerID=8YFLogxK
U2 - 10.3171/2016.3.SPINE1640
DO - 10.3171/2016.3.SPINE1640
M3 - Article
C2 - 27231810
AN - SCOPUS:85012849135
SN - 1547-5654
VL - 25
SP - 545
EP - 555
JO - Journal of Neurosurgery: Spine
JF - Journal of Neurosurgery: Spine
IS - 5
ER -