Pump in parallel-mechanical assistance of partial cavopulmonary circulation using a conventional ventricular assist device

Pranava Sinha, Nina Deutsch, Kanishka Ratnayaka, Dingchao He, Murfad Peer, Mustafa Kurkluoglu, Mark Nuszkowski, Erin Montague, Gerald Mikesell, David Zurakowski, Richard Jonas

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Mechanical assistance of systemic single ventricle is effective in pulling blood through a cavopulmonary circuit. In patients with superior cavopulmonary connection, this strategy can lead to arterial desaturation secondary to increased inferior caval flow. We hypothesized that overall augmentation in cardiac output with mechanical assistance compensates for the drop in oxygen saturation thereby maintaining tissue oxygen delivery (DO 2 ). Bidirectional Glenn (BDG) was established in seven swine (25 kg) after a common atrium had been established by balloon septostomy. Mechanical circulatory assistance of the single ventricle was achieved using an axial flow pump with ventricular inflow and aortic outflow. Cardiac output, mean pulmonary artery pressure (PAP), common atrial pressure (left atrial pressure [LAP]), arterial oxygen saturation (SaO 2 ), partial pressure of arterial oxygen (PaO 2 ), and DO 2 were compared between assisted and nonassisted circulation. Significant augmentation of cardiac output was achieved with mechanical assistance in BDG circulation (BDG: median [interquartile range {IQR}], 0.8 [0.9-1.15] L/min versus assisted BDG: median [IQR], 1.5 [1.15-1.7] L/min; p = 0.05). Although oxygen saturations and PaO 2 trended to be lower with assistance (SaO 2 ; BDG: median [IQR], 43% [32-57%]; assisted BDG: median [IQR], 32% [24-35%]; p = 0.07) (PaO 2 ; BDG: median [IQR], 24 [20-30] mm Hg; assisted BDG: median [IQR], 20 [17-21] mm Hg; p = 0.08), DO 2 was unchanged with mechanical assistance (BDG: median [IQR], 94 [35-99] ml/min; assisted BDG: median [IQR], 79 [63-85] ml/min; p = 0.81). No significant change in the LAP or PAP was observed. In the setting of superior cavopulmonary connection/single ventricle, the systemic ventricular assistance with a ventricular assist device (VAD) leads to increase in cardiac output. Arterial oxygen saturations however may be lower with mechanical assistance, without any change in DO 2 .

Original languageEnglish (US)
Pages (from-to)238-244
Number of pages7
JournalASAIO Journal
Volume64
Issue number2
DOIs
StatePublished - 2018
Externally publishedYes

Bibliographical note

Publisher Copyright:
Copyright © 2017 by the ASAIO.

Keywords

  • Cavopulmonary connection
  • Circulatory support devices
  • Congenital heart disease
  • Univentricular heart

Fingerprint

Dive into the research topics of 'Pump in parallel-mechanical assistance of partial cavopulmonary circulation using a conventional ventricular assist device'. Together they form a unique fingerprint.

Cite this