Repeatability of a dual gradient-recalled echo MRI method for monitoring post-isometric contraction blood volume and oxygenation changes

Otto A. Sanchez, E. A. Louie, E. A. Copenhaver, B. M. Damon

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

The purpose of this study was to assess the repeatability of a dual gradient-recalled echo (GRE) muscle functional MRI technique. On 2 days, subjects (n=8) performed 10 s isometric dorsiflexion contractions under conditions of: (1) maximal voluntary contraction (MVC), (2) 50% MVC (50% MVC), or (3) 50% MVC with concurrent proximal arterial cuff occlusion (50% MVCcuff). Functional MRI data were acquired using single-slice dual GRE (TR/TE=1000/6, 46 ms)-echo planar imaging for 20 s before, during, and for 180 s after each contraction. The mean signal intensity (SI) time courses at each TE (SI6 and SI46, reflecting variations in blood volume and %HbO2, respectively) from the tibialis anterior (TA) and extensor digitorum longus (EDL) muscles were characterized with the post-contraction change in SI and the time-to-peak SI (DSI and TTP, respectively). ΔSI6 following an MVC was 36% higher than that obtained after a 50% MVC (p=0.048). For ΔSI6, the highest intraclass correlation coefficients (ICCs) were observed for the TA muscle in the 50% MVC and MVC conditions, with values of 0.83 (p=0.01) and 0.88 (p=0.005), respectively. Bland-Altman plots revealed repeatability coefficients (RCs) for the 50% MVC and MVC conditions in the TA muscle of 1.9 and 1.4, respectively. The most repeatable measures for ΔSI46 were obtained for the 50% MVC and MVC conditions in the EDL muscle (p=0.01 and p=0.04, respectively). Bland-Altman plots revealed RC's for 50% MVC and MVC conditions in the EDL muscle of 3.9 and 5.7, respectively. ΔSI6 and ΔSI46 increased as a function of the contraction intensity. The repeatability of the method depends on the muscle and contraction condition being evaluated, and in general, is higher following an MVC.

Original languageEnglish (US)
Pages (from-to)753-761
Number of pages9
JournalNMR in biomedicine
Volume22
Issue number7
DOIs
StatePublished - 2009

Keywords

  • %HbO2
  • Blood volume
  • Isometric contractions
  • Microvasculature
  • Repeatability
  • mfMRI

Fingerprint

Dive into the research topics of 'Repeatability of a dual gradient-recalled echo MRI method for monitoring post-isometric contraction blood volume and oxygenation changes'. Together they form a unique fingerprint.

Cite this