T1 - Volumetric analysis of abdominal aortic aneurysm
AU - Baskin, Kevin M.
AU - Kusnick, Catherine A.M.D.
AU - Shamsolkottabi, Susanne
AU - Lang, Elvira V.
AU - Corson, J. D.
AU - Stanford, William
AU - Thompson, Brad H.
AU - Hoffman, Eric A.
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 1996
Y1 - 1996
N2 - The purpose of this study was to develop a valid, reliable and accurate system of measurement of abdominal aortic aneurysms, using volumetric analysis of x-ray computed tomographic data. This study evaluates illustrative cases, and compares measurements of AAA phantoms, using standard 2D versus volumetric methods. To validate the volumetric analysis, four phantom aneurysms were constructed in a range of diameters (4.5 - 7.0 cm) which presents the greatest management challenge to the clinician. These phantoms were imaged using a Toshiba Xpress SX helical CT. Separate scans were obtained at conventional (10 mm × 10 mm) and thin slice (5 mm × 5 mm) collimations. The thin slices were reconstructed at 2 mm intervals. Data from each of the 96 scans were interpreted using a standard 2D approach, then analyzed using task-oriented volumetric software. We evaluate patient assessments, and compare greatest outer diameters of phantoms, by standard versus volumetric methods. Qualitative differences between solutions based on standard versus volumetric analysis of illustrative patient cases are substantial. Expert radiologists' standard measurements of phantom aneurysms are highly reliable (r 2 = 0.901 - 0.958; p < 0.001), but biased toward significant overestimation of aneurysm diameters in the range of clinical interest. For the same phantoms, volumetric analysis was both more reliable (r 2 = 0.986 - 0.996; p < 0.001), and more accurate, with no significant bias in the range of interest. Volumetric analysis promotes selection of more valid management strategies, by providing vital information not otherwise available, and allowing more reliable and accurate assessment of abdominal aortic aneurysms. It is particularly valuable in the presence of aortic tortuosity, vessel eccentricity, and uncertain involvement of critical vessels.
AB - The purpose of this study was to develop a valid, reliable and accurate system of measurement of abdominal aortic aneurysms, using volumetric analysis of x-ray computed tomographic data. This study evaluates illustrative cases, and compares measurements of AAA phantoms, using standard 2D versus volumetric methods. To validate the volumetric analysis, four phantom aneurysms were constructed in a range of diameters (4.5 - 7.0 cm) which presents the greatest management challenge to the clinician. These phantoms were imaged using a Toshiba Xpress SX helical CT. Separate scans were obtained at conventional (10 mm × 10 mm) and thin slice (5 mm × 5 mm) collimations. The thin slices were reconstructed at 2 mm intervals. Data from each of the 96 scans were interpreted using a standard 2D approach, then analyzed using task-oriented volumetric software. We evaluate patient assessments, and compare greatest outer diameters of phantoms, by standard versus volumetric methods. Qualitative differences between solutions based on standard versus volumetric analysis of illustrative patient cases are substantial. Expert radiologists' standard measurements of phantom aneurysms are highly reliable (r 2 = 0.901 - 0.958; p < 0.001), but biased toward significant overestimation of aneurysm diameters in the range of clinical interest. For the same phantoms, volumetric analysis was both more reliable (r 2 = 0.986 - 0.996; p < 0.001), and more accurate, with no significant bias in the range of interest. Volumetric analysis promotes selection of more valid management strategies, by providing vital information not otherwise available, and allowing more reliable and accurate assessment of abdominal aortic aneurysms. It is particularly valuable in the presence of aortic tortuosity, vessel eccentricity, and uncertain involvement of critical vessels.
UR - http://www.scopus.com/inward/record.url?scp=0029700763&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029700763&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0029700763
SN - 0819420840
SN - 9780819420848
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 323
EP - 337
BT - Proceedings of SPIE - The International Society for Optical Engineering
A2 - Hoffman, Eric A.
T2 - Medical Imaging 1996: Physiology and Function from Multidimensional Images
Y2 - 11 February 1996 through 13 February 1996
ER -